Industrial FRP Blowers
Our rugged fans are designed to exhaust corrosive air in chemical environments. Housings and
impellers are constructed of premium grade vinyl ester resin using "C" chemical glass surface veil inside and outside or optional nexus veil for protection. Verantis has over 40 years experience designing and manufacturing fans.
Custom or stock fans are available.
Centrifugal Fans Models CLUB, CLM, CMH, CH, and CHP
- Capacities from 50 CFM to 150,000 CFM at static pressures up to 40” WC.
- Sizes ranging from 6” to 88” diameter.
- Extremely low vibration down to 0.025 in./sec. for direct drive and 0.0785 in./sec. for belt drive.
- Impeller types available: Paddle-wheel, backward-curved, and forward-curve radial tip.
- Lightweight FRP construction reducing structural support requirements.
- Spark resistant construction.
- Complete accessories available including dampers and variable frequency drives.
- All surfaces have “C” grade glass veil or option Nexus veil to protect against weathering, fumes spillage, and ultraviolet attack.
Click here to visit the Centrifugal Fan Showcase!
Axial Fans – Mode FL and FLR
- Capacities from 100 CFM to 110,000 CFM at static pressures up to 2.5" WC.
- 11 sizes available from 12" to 72" diameter.
- Both duct mount and roof mount styles available.
Custom Fans and Accessories
- Many arrangements available: 10, 9, 8, 4 or 1-E.
- Special designs for specific applications.
- Acoustical treatments: housing insulation, silencers and enclosures.
- Customer selected resin systems.
- Alloy shafts.
- Alloy impellers for high tip-speed applications.
- Shaft seals: Stuffing box, Teflon, mechanical or other.
- Graphite impregnation for conductivity.
- Inlet boxes.
- Multi-stage fans for high static pressure.
- Removable bearing assembly (axial fans).
- Other accessories to meet your needs.
Fast Track Fans
Need a fan NOW? No problem. Get a corrosion resistant Fast Track Fan within 5 days of your order.
Choose from the following:
Centrifugal Fans (8" to 25" diameter)
- Model Series CLUB, CMHP, CLMP
- Arrangement #10
- Backward curved and paddle-wheel style impellers
- FRP drain
- Rectangular outlet flange
- Plain round inlet
- "Easy Maintenance" style shaft to hub connection
Features:
- Fixed belt drives
- All vinyl ester resin and "C" (chemical) glass veil laminate surfaces
- TEFC motor
- Weather Resistant OSHA canopy
- Flow rates up to 13,000 ACFM
- Pressure drops up to 17" w.g.
Axial Fans (12", 18" or 24" diameter)
- Model Series FL (Duct Mounted)
- Drilled inlet and outlet flanges
- Model Series FLR (Roof Mounted)
- Optional stack cap with gravity damper