Semiconductor chip manufacturing utilizes a variety of inorganic acids and ammonia solutions. Mixing of acid gases and ammonia in a ventilation system can result in a gas phase reaction producing very fine particulate that is difficult and expensive to remove. For this reason a large semiconductor foundry on the west coast decided to pre-treat the exhaust from the ammonia sources prior to mixing with the general ventilation from the acid sources. The volume at each source was relatively small (1,500 – 2,500 CFM) and the customer’s preference was to treat each source independently to avoid an elaborate duct arrangement.
Verantis had the perfect solution, our packaged MiniScrubber. The polypropylene units are designed as a complete compact assembly with support frame, top mounted fan, and automated controls. The unique sprayer design eliminates the need for a recirculation pump and piping reducing both energy usage and maintenance requirements. Using dilute sulfuric solution, the system is able to achieve > 95% ammonia removal.

| Application | Wafer Fabrication Process Ventilation |
| Exhaust Volume | 2,500 ACFM |
| Exhaust Temperature | Ambient |
| Exhaust Pressure | 5” W.C. |
| Contaminant | Ammonia |
| Removal Efficiency | 95% |
| Scrubbing Solution | Dilute H2SO4 |
| Materials of Construction | Polypropylene |